Switch and Jumper Settings
Switch# Position Description
8 - Open YES Diagnostic mode
Closed* NO " * = factory default setting
7 - Closed* NO reset on power-up and SCSI reset
Open YES "
6 - Open* Data block size = 8192 bytes
Closed " 8320
5,4 Open* Reserved
3,2,1 SCSI address 3=MSB, 1=LSB Open=0, Closed=1
Jumper Plugs:
+5V ----|>|-----o JP5 o-------+------- Pin 26
|
+---o JP6 o-------+
|
? <-----+---o JP7 o------------ +5V
JP5 is for those systems that require terminator power to be supplied
by the tape drive on SCSI Pin 26 for external terminators. The
internal terminators must be REMOVED from the unit when using this option.
JP6 is for those systems that supply terminator power to the tape drive.
Only the SCSI terminators are powered in this option. The internal
terminators must be INSTALLED if the drive is the last device on
the SCSI cable.
JP7 is preset as a factory default for those systems that use no
terminator power. The internal terminators must be INSTALLED if the
drive is the last device on the SCSI cable.