PowerKey
This document contains experimentally-observed behavior of the ADB protocol of the Sophisticated Circuits PowerKey Classic (PK-1). It contains enough information to satisfactorally emulate the device, however, a few unknowns exist.
The PowerKey's default address is 0x7 and its default handler ID is 0x22.
Register 0
Register 0 is a 16-bit register. Its upper byte can be written by the host using a Listen 0 command, however its lower byte is read-only and its value in the Listen 0 command will be ignored. Register 0 can only be read when its bit 8 is set, otherwise Talk 0 produces no reply.
| Bit | Description | | ---- | ---------------------------------------------------------------------------------------------------- | | 15:9 | Undetermined, appears to always be set to 0 | | 8 | If set, Talk 0 returns the contents of register 0; if clear, it returns nothing | | 7 | If set, relay is closed and outlets are powered; if clear, relay is open and outlets are not powered | | 6 | If set, relay was last closed as a result of register 1 overflowing | | 5 | If set, relay was last closed as a result of the power key being pressed on the keyboard | | 4:2 | Undetermined, appears to always be set to 0 | | 1:0 | Undetermined, appears to always be set to 1 |
Registers 1 and 2
Registers 1 and 2 are both readable (with Talk) and writable (with Listen) 32-bit timers which increment 60 times per second when their high byte is nonzero. When register 1 overflows from 0xFFFFFFFF to 0, if the relay was open, it closes and sets bits 7 and 6 of register 0. When register 2 overflows from 0xFFFFFFFF to 0, if the relay was closed, it opens and clears bits 7, 6, and 5 of register 0.
Register 3
The Exceptional Event bit is always set. The Service Request Enable bit is always clear.
Device Information
The software always appears to report the PowerKey Classic as having a serial number of 0 and a firmware revision of 1.4. No register on the device appears to contain this information.